• DocumentCode
    3268791
  • Title

    3D Bayesian Tracking with a Single Imager for Real-Time Image Guidance in Prostate Radiation Therapy

  • Author

    Li, Ruijiang ; Fahimian, Benjamin ; Xing, Lei

  • Author_Institution
    Dept. of Radiat. Oncology, Stanford Univ., Stanford, CA, USA
  • Volume
    2
  • fYear
    2011
  • fDate
    18-21 Dec. 2011
  • Firstpage
    210
  • Lastpage
    214
  • Abstract
    Intra-fraction internal anatomy motion is one of the major causes of the uncertainty in prostate radiation therapy. Real-time tracking of the intra-fraction prostate motion during radiation therapy is necessary to truly benefit from the highly conformal dose distribution. With the widespread use of kV on-board imaging devices, it is desirable to estimate the 3D tumor position from a single x-ray imager during treatment delivery. In this work, we will present an improved real-time 3D Bayesian tracking algorithm with an online update scheme. By incorporating all previously acquired images during dose delivery and updating the motion probability density function in an online fashion, the algorithm is able to track large and abrupt changes that are typical of prostate motion. The flexible Bayesian formulation allows one to easily incorporate this information and obtain the 3D motion with minimal computational cost. The new tracking algorithm has been tested on actual prostate trajectories recorded with implanted electromagnetic transponders for a total of 10 patients. The new algorithm outperformed a previous one with a fixed prior built from the original setup images (Li et al. 2011). It was found that with the new algorithm, the mean 3D tracking error is about 0.15 mm and the 95th percentile error is about 0.45 mm on average for all the patients. The proposed 3D tracking algorithm is useful for real-time image guidance in prostate radiation therapy.
  • Keywords
    Bayes methods; cancer; electromagnetic devices; image motion analysis; image sensors; medical image processing; object tracking; radiation therapy; real-time systems; tumours; 3D tumor position estimation; conformal dose distribution; electromagnetic transponders; intrafraction internal anatomy motion; motion probability density function; on-board imaging devices; prostate radiation therapy; real-time 3D Bayesian tracking algorithm; real-time image guidance; treatment delivery; x-ray imager; Bayesian methods; Imaging; Real time systems; Three dimensional displays; Tracking; Tumors; X-ray imaging; Bayesian tracking; image guidance; prostate cancer; radiation therapy; real-time;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Machine Learning and Applications and Workshops (ICMLA), 2011 10th International Conference on
  • Conference_Location
    Honolulu, HI
  • Print_ISBN
    978-1-4577-2134-2
  • Type

    conf

  • DOI
    10.1109/ICMLA.2011.10
  • Filename
    6147675