• DocumentCode
    3272768
  • Title

    An EMI test methodology for network devices

  • Author

    Chang, Y.C. ; Chen, Francis ; Liau, Paul Y.

  • Author_Institution
    Dept. of Electr. Eng., Nantai Inst. of Technol., Tainan, Taiwan
  • fYear
    1999
  • fDate
    1999
  • Firstpage
    662
  • Lastpage
    665
  • Abstract
    A series of EMI tests for network devices were designed and completed The frequency ranged from 30 to 900 MHz with an increment of 10 MHz. Three EUT exposure cable configurations were applied to this test for measuring horizontal and vertical polarization radiation
  • Keywords
    UHF measurement; cable testing; computer networks; computer testing; electromagnetic interference; electromagnetic wave polarisation; electronic equipment testing; twisted pair cables; 30 to 900 MHz; EMI test methodology; EUT exposure cable configurations; HF; UHF; VHF; computer network; frequency range; horizontal polarization radiation measurement; network devices; vertical polarization radiation measurement; Antenna measurements; Antenna radiation patterns; Background noise; Electromagnetic interference; Electromagnetic radiation; Electromagnetic wave polarization; Frequency measurement; Noise figure; Noise measurement; Testing;