DocumentCode
3272817
Title
Determination of a relevant criterion to characterize differential conducted perturbations generated by low frequency converters
Author
Guitton, Fabrice ; Magnon, Didier
Author_Institution
Tours Univ., France
fYear
1999
fDate
1999
Firstpage
678
Lastpage
681
Abstract
This paper demonstrates that the slope is not an appropriate parameter to characterize a waveform regarding conducted electromagnetic perturbations. On the other hand, a relevant criterion is made conspicuous: it defines the maximum slope deviation between two segments forming a signal. This criterion is validated by a waveform with a maximum slope of 400 mA/μs
Keywords
convertors; electric current; electromagnetic interference; STFT; conducted EMI measurement; conducted electromagnetic perturbations; current waveform characterisation; differential conducted perturbations; low frequency converters; maximum slope deviation; short time Fourier transform; Character generation; Electromagnetic interference; Frequency conversion; Frequency measurement; Frequency response; Impedance; Measurement standards; Power generation; Signal analysis; Signal resolution;
fLanguage
English
Publisher
ieee
Conference_Titel
Electromagnetic Compatibility, 1999 International Symposium on
Conference_Location
Tokyo
Print_ISBN
4-9980748-4-9
Type
conf
DOI
10.1109/ELMAGC.1999.801419
Filename
801419