• DocumentCode
    3274042
  • Title

    Automatic detection of small spherical lesions using multiscale approach in 3D medical images

  • Author

    Fazlollahi, Amir ; Meriaudeau, Fabrice ; Villemagne, Victor L. ; Rowe, Christopher C. ; Desmond, Patricia M. ; Yates, Paul A. ; Salvado, Olivier ; Bourgeat, Pierrick

  • Author_Institution
    Australian e-Health Res. Centre-BioMedIA, R. Brisbane & Women´s Hosp., Herston, QLD, Australia
  • fYear
    2013
  • fDate
    15-18 Sept. 2013
  • Firstpage
    1158
  • Lastpage
    1162
  • Abstract
    Automated detection of small, low level shapes such as circular/spherical objects in images is a challenging computer vision problem. For many applications, especially microbleed detection in Alzheimer´s disease, an automatic pre-screening scheme is required to identify potential seeds with high sensitivity and reasonable specificity. A new method is proposed to detect spherical objects in 3D medical images within the multi-scale Laplacian of Gaussian framework. The major contributions are(1)breaking down 3D sphere detection into 1D line profile detection along each coordinate dimension, (2) identifying center of structures bynormalizing the line response profile and (3) employing eigenvalues of the Hessian matrix at optimum scale for the center points to determine spherical objects. The method is validated both on simulated data and susceptibility weighted MRI images with ground truth provided by a medical expert. Validation results demonstrate that the current approach has higher performance in terms of sensitivity and specificity and is effective in detecting adjacent microbleeds, with invariance to intensity, orientation, translation and object scale.
  • Keywords
    Gaussian processes; Hessian matrices; Laplace equations; biomedical MRI; computer vision; diseases; eigenvalues and eigenfunctions; medical image processing; object detection; 1D line profile detection; 3D medical images; 3D sphere detection; Alzheimer´s disease; Gaussian framework; Hessian matrix; adjacent microbleed detection; automatic prescreening scheme; automatic small spherical lesion detection; circular objects; computer vision problem; eigenvalues; line response profile; multiscale Laplacian; multiscale approach; spherical object detection; spherical objects; susceptibility weighted MRI images; Biomedical imaging; Eigenvalues and eigenfunctions; Lesions; Object recognition; Optimized production technology; Shape; Three-dimensional displays; 3D sphere detection; Laplacian of Gaussian; center detection; cerebral micro bleed; multi-scale;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Image Processing (ICIP), 2013 20th IEEE International Conference on
  • Conference_Location
    Melbourne, VIC
  • Type

    conf

  • DOI
    10.1109/ICIP.2013.6738239
  • Filename
    6738239