• DocumentCode
    3276710
  • Title

    Magnetron injection gun measurements

  • Author

    Ives, R. Lawrence ; Collins, George ; Borchard, Philipp

  • Author_Institution
    Calabazas Creek Res., Inc., San Mateo, CA
  • fYear
    2008
  • fDate
    15-19 Sept. 2008
  • Firstpage
    1
  • Lastpage
    2
  • Abstract
    Several magnetron injection gun cathodes have been measured for temperature and emission uniformity. The measurements confirm results in Russia that the quality of many MIG cathodes is not sufficient for efficient gyrotron operation. This presentation will present recent cathode measurements and identify known issues. A design will be presented that provides a solution for several of these issues.
  • Keywords
    cathodes; electron guns; gyrotrons; magnetrons; temperature measurement; cathodes; gyrotron operation; magnetron injection gun measurements; temperature measurements; Assembly; Cathodes; Coils; Current measurement; Gyrotrons; Probes; Rough surfaces; Temperature measurement; Test facilities; Testing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Infrared, Millimeter and Terahertz Waves, 2008. IRMMW-THz 2008. 33rd International Conference on
  • Conference_Location
    Pasadena, CA
  • Print_ISBN
    978-1-4244-2119-0
  • Electronic_ISBN
    978-1-4244-2120-6
  • Type

    conf

  • DOI
    10.1109/ICIMW.2008.4665636
  • Filename
    4665636