    High efficiency submillimeter-wave imaging array

  • Author

    Llombart, Nuria ; Skalare, Anders ; Gill, John J. ; Siegel, Peter H.

  • Author_Institution
    Jet Propulsion Lab., California Inst. of Technol., Pasadena, CA
  • fYear
    2008
  • fDate
    15-19 Sept. 2008
  • Firstpage
    1
  • Lastpage
    3
  • Abstract
    The period of a focal array is limited by the angular sampling and the f number of the system. This fact will limit the efficiency of imaging array systems to around 50%. Recently it been demonstrated that the use of a dielectric layer on top of an array of apertures can improve this efficiency limit. In this paper, we describe a similar structure that improves the efficiency in imaging applications and that it is easy to manufacture due to its compatibility with planar lithographic techniques.
  • Keywords
    focal planes; submillimetre wave imaging; angular sampling; dielectric layer; f number; focal array period; high efficiency submillimeter-wave imaging array; planar lithographic techniques; Apertures; Dielectric constant; Geometry; Image resolution; Laboratories; Propulsion; Pulp manufacturing; Radio frequency; Sampling methods; Submillimeter wave technology;