DocumentCode :
3277759
Title :
A stepping algorithm for transient analysis of distributed networks
Author :
Lu, Linchao ; Nakhla, Michel S. ; Zhang, Qi-Jun
Author_Institution :
Dept. of Electron., Carleton Univ., Ottawa, Ont., Canada
Volume :
4
fYear :
1992
fDate :
3-6 May 1992
Firstpage :
1957
Abstract :
An alternative approach for enhancing the accuracy of numerical inversion of the Laplace transform is presented. A reinitialization technique based on the numerical inversion of the Laplace transform (NILT) is described. The method uses a stepping algorithm to reinitialize the reference time point for NILT within a distributed network environment to improve the simulation accuracy of distributed networks and systems with long transients
Keywords :
Laplace transforms; distributed parameter networks; linear network analysis; transient response; Laplace transform; distributed networks; numerical inversion; reference time point; reinitialization technique; stepping algorithm; transient analysis; Admittance; Frequency domain analysis; Laplace equations; Multiconductor transmission lines; Power system transients; Transient analysis; Transmission line matrix methods; Transmission lines; Vectors; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Circuits and Systems, 1992. ISCAS '92. Proceedings., 1992 IEEE International Symposium on
Conference_Location :
San Diego, CA
Print_ISBN :
0-7803-0593-0
Type :
conf
DOI :
10.1109/ISCAS.1992.230425
Filename :
230425
Link To Document :
بازگشت