• DocumentCode
    3277759
  • Title

    A stepping algorithm for transient analysis of distributed networks

  • Author

    Lu, Linchao ; Nakhla, Michel S. ; Zhang, Qi-Jun

  • Author_Institution
    Dept. of Electron., Carleton Univ., Ottawa, Ont., Canada
  • Volume
    4
  • fYear
    1992
  • fDate
    3-6 May 1992
  • Firstpage
    1957
  • Abstract
    An alternative approach for enhancing the accuracy of numerical inversion of the Laplace transform is presented. A reinitialization technique based on the numerical inversion of the Laplace transform (NILT) is described. The method uses a stepping algorithm to reinitialize the reference time point for NILT within a distributed network environment to improve the simulation accuracy of distributed networks and systems with long transients
  • Keywords
    Laplace transforms; distributed parameter networks; linear network analysis; transient response; Laplace transform; distributed networks; numerical inversion; reference time point; reinitialization technique; stepping algorithm; transient analysis; Admittance; Frequency domain analysis; Laplace equations; Multiconductor transmission lines; Power system transients; Transient analysis; Transmission line matrix methods; Transmission lines; Vectors; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Circuits and Systems, 1992. ISCAS '92. Proceedings., 1992 IEEE International Symposium on
  • Conference_Location
    San Diego, CA
  • Print_ISBN
    0-7803-0593-0
  • Type

    conf

  • DOI
    10.1109/ISCAS.1992.230425
  • Filename
    230425