• DocumentCode
    3277968
  • Title

    Measurement and analysis of electric potential decay in corona charged low-density polyethylene films

  • Author

    Xu, Z. ; Zhang, L. ; Chen, G.

  • Author_Institution
    School of Electronics and Computer Science, University of Southampton, Southampton, SO17 1BJ, United Kingdom. E-mail: zx04r@ecs.soton.ac.uk
  • fYear
    2007
  • fDate
    8-13 July 2007
  • Firstpage
    454
  • Lastpage
    457
  • Abstract
    In this paper, corona charged LDPE film was tested using a standard static potential monitor and the pulsed electro-acoustic (PEA) technique to observe the surface potential decay. A wide range of voltages and different corona charging times, different sample thicknesses and multi-layer films were used to demonstrate influential factors for surface potential decay. These provide a direct experimental evidence to support the bulk transport process. An important finding from the PEA results is that bipolar charge injection takes place during corona charging process and in subsequently decay process. The new evidence challenges the existing surface potential decay models which were developed based on a single charge carrier injection.
  • Keywords
    Corona; Current measurement; Electric potential; Electric variables measurement; Monitoring; Plastic films; Polyethylene; Pulsed electroacoustic methods; Surface charging; Testing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Solid Dielectrics, 2007. ICSD '07. IEEE International Conference on
  • Conference_Location
    Winchester, UK
  • Print_ISBN
    1-4244-0750-8
  • Electronic_ISBN
    1-4244-0751-6
  • Type

    conf

  • DOI
    10.1109/ICSD.2007.4290849
  • Filename
    4290849