DocumentCode :
3279140
Title :
Point-of-use measurement of salivary cortisol levels
Author :
Yamaguchi, Masaki ; Yoshikawa, Suguru ; Tahara, Yusuke ; Niwa, Daisuke ; Imai, Yoshikatsu ; Shetty, Vivek
Author_Institution :
Grad. Sch. of Eng., Iwate Univ., Morioka, Japan
fYear :
2009
fDate :
25-28 Oct. 2009
Firstpage :
343
Lastpage :
346
Abstract :
The objective is to develop a novel methodology to analyze cortisol levels in saliva as an index of neuroendocrine response. In order to realize a portable, rapid and hand held biosensor of cortisol, we proposed an immuno-chromatographic test-strip based biosensor consisting of a disposable test-strip and a monitor. A fabricated disposable type test-strip has a size of 5 × 1.5 × 50 mm3. In order to realize an immuno-chromatographic test-strip, a glucose oxidase (GOD)-cortisol conjugate was newly synthesized, because the speed and selectivity of immunological reactions is particularly attractive as a strategy for molecular recognition of cortisol. The synthesized molecule was identified as the GOD-cortisol conjugate by both its molecular weight and specific detection of cortisol. Three min after addition of GOD enzyme assay solution, a color change reaction at a test line was observed. The R2 value for the calibration curve of the cortisol test strip was 0.95, and the relationship between its reflectance, r, and the cortisol level was r = 0.629 (1-0.232e(-1.78 × cortisol)). The fabricated cortisol biosensor enabled us to analyze cortisol concentrations between 1 - 10 ng/ml within 25 min of dropping a cortisol solution on the test strip. Thus, it is suggested that the cortisol biosensor may possibly be used for point-of-use measurements in hospitals.
Keywords :
biochemistry; biomedical measurement; biosensors; chromatography; enzymes; molecular biophysics; molecular weight; reflectivity; GOD-cortisol conjugate; biosensor; color change reaction; cortisol levels; glucose oxidase-cortisol conjugate; immuno-chromatographic test-strip; immunological reactions; molecular recognition; molecular weight; neuroendocrine response; point-of-use measurement; reflectance; saliva; size 1.5 mm; size 5 mm; size 50 mm; time 25 min; Biochemistry; Biosensors; Calibration; Hospitals; Immune system; Monitoring; Reflectivity; Strips; Sugar; Testing;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Sensors, 2009 IEEE
Conference_Location :
Christchurch
ISSN :
1930-0395
Print_ISBN :
978-1-4244-4548-6
Electronic_ISBN :
1930-0395
Type :
conf
DOI :
10.1109/ICSENS.2009.5398143
Filename :
5398143
Link To Document :
بازگشت