• DocumentCode
    3280326
  • Title

    Millimeter wave synthetic thinned aperture radiometer

  • Author

    Kangaslahti, Pekka ; Tanner, Alan ; Gaier, Todd ; Lambrigtsen, Bjorn ; O´Dwyer, Ian ; Pukala, David

  • Author_Institution
    Jet Propulsion Lab., Pasadena, CA
  • fYear
    2008
  • fDate
    15-19 Sept. 2008
  • Firstpage
    1
  • Lastpage
    2
  • Abstract
    Imaging of temperature and humidity profiles of the atmosphere on a global scale with high temporal and spatial resolution requires a large aperture millimeter wave radiometer on geostationary orbit. We developed a prototype 50 GHz millimeter wave synthetic aperture radiometer and low noise amplifier (LNA) MMICs and receiver technology for a 180 GHz synthetic aperture system. The 50 GHz system was tested in laboratory and in field with a 4-meter target disk by refocusing the array to near-field by digital phase corrections. The 180 GHz system development included novel 180 GHz MMIC LNAs that provide more than 100 GHz of bandwidth with more than 15 dB of gain and a noise figure of 3.7 dB.
  • Keywords
    MMIC; low noise amplifiers; millimetre wave detectors; radiometers; LNA; MMIC; digital phase corrections; frequency 50 GHz; geostationary orbit; humidity profiles; low noise amplifier; millimeter wave synthetic thinned aperture radiometer; noise figure; receiver technology; synthetic aperture system; temperature profiles; Apertures; Atmosphere; High-resolution imaging; Humidity; MMICs; Millimeter wave technology; Phased arrays; Radiometry; Spatial resolution; Temperature;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Infrared, Millimeter and Terahertz Waves, 2008. IRMMW-THz 2008. 33rd International Conference on
  • Conference_Location
    Pasadena, CA
  • Print_ISBN
    978-1-4244-2119-0
  • Electronic_ISBN
    978-1-4244-2120-6
  • Type

    conf

  • DOI
    10.1109/ICIMW.2008.4665815
  • Filename
    4665815