• DocumentCode
    3280601
  • Title

    The Research of ECT system based on rotational electrodes array

  • Author

    Guofu, Qiu ; Yanjun, Zhao ; Yuqin, Zhang

  • Author_Institution
    Sch. of Mech. Eng., Nanjing Univ. of Sci. & Technol., Nanjing, China
  • fYear
    2011
  • fDate
    15-17 April 2011
  • Firstpage
    867
  • Lastpage
    869
  • Abstract
    Owing to the number limit of electrodes, the resolution is low in ECT system currently. But increasing the number of electrode plates will lead to decrease the area of electrodes and lower the SNR. In this paper, with the method of electrodes subdividing and rotational combination, the ECT measurement system of rotational capacitor electrodes array is built, which can increase projection data and improve reconstruction image resolution without decreasing the area of electrodes.
  • Keywords
    capacitance measurement; capacitive sensors; computerised instrumentation; electrodes; image reconstruction; image resolution; image sensors; tomography; ECT measurement system; ECT system; SNR; electrode plates; image reconstruction; image resolution; projection data; rotational capacitor electrode array; Arrays; Artificial neural networks; Capacitors; Electrodes; Image reconstruction; Image resolution; Pipelines; BP network algorithm; ECT system; Rotational electrodes array;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electric Information and Control Engineering (ICEICE), 2011 International Conference on
  • Conference_Location
    Wuhan
  • Print_ISBN
    978-1-4244-8036-4
  • Type

    conf

  • DOI
    10.1109/ICEICE.2011.5777627
  • Filename
    5777627