    Variable sensitivity online optical fibre radiation dosimeter

  • Author

    Keeffe, S.O. ; Lewis, E. ; Santhanam, A. ; Rolland, J.P.

  • Author_Institution
    Opt. Fibre Sensors Res. Centre, Univ. of Limerick, Limerick, Ireland
  • fYear
    2009
  • fDate
    25-28 Oct. 2009
  • Firstpage
    787
  • Lastpage
    790
  • Abstract
    The use of Poly Methyl MethAcrylate (PMMA) optical fibres for monitoring a wide range of radiation doses, for a multi-functional dosimeter, is being investigated. The sensitivity of the fibre to ionising radiation is shown to be dependant on wavelength, with the sensitivity increasing with decreasing wavelength. The fibres exhibit high sensitivity, as high as 0.6dBm-1/kGy, and are capable of monitoring dose ranges between 30Gy and 45kGy. This exceeds the sensing range of all currently commercially available PMMA slab sensors. By carefully selecting the monitoring wavelength, the exact sensitivity and dose range can be achieved, thereby allowing the dosimeter to be suitable for a wide range of applications.
  • Keywords
    dosimeters; fibre optic sensors; optical polymers; ionising radiation; polymethyl methacrylate; radiation doses; variable sensitivity online optical fibre radiation dosimeter; Cancer; Costs; Dosimetry; Gamma rays; Ionizing radiation; Optical fiber sensors; Optical fibers; Pathogens; Radiation monitoring; Slabs;