Title
Advances in cable and conduit sealing for Class 1 hazardous locations
Author
Ballard, Alonza W. ; Alexander, Robert B.
Author_Institution
Crouse-Hinds, Syracuse, NY, USA
fYear
1996
fDate
23-25 Sep 1996
Firstpage
107
Lastpage
113
Abstract
Recent changes to the National Electrical Code (NEC) and to Underwriters Laboratories (UL) standards, coupled with technological changes, present new opportunities for ease of installation, labor saving and reliability of power cables and conduits. New techniques for factory sealing in Division 1 and 2 are explained, as are various methods to achieve 40% conduit fill for sealing fittings. New sealing methods for multiconductor cables in conduits are covered as well as new requirements for metal-clad cable seals for Division 1
Keywords
cable jointing; cable laying; cable sheathing; electric conduits; power cables; safety; seals (stoppers); standards; Class 1 hazardous locations; National Electrical Code; Underwriters Laboratories; factory sealing techniques; installation; metal-clad cable seals; multiconductor cables; power cable; power cable conduits; reliability; standards; Cable shielding; Code standards; Gases; Hazardous materials; Laboratories; Materials reliability; National electric code; Paper technology; Seals; Wire;
fLanguage
English
Publisher
ieee
Conference_Titel
Petroleum and Chemical Industry Conference, 1996, Record of Conference Papers. The Institute of Electrical and Electronics Engineers Incorporated Industry Applications Society 43rd Annual
Conference_Location
Philadelphia, PA
ISSN
0090-3507
Print_ISBN
0-7803-3587-2
Type
conf
DOI
10.1109/PCICON.1996.564872
Filename
564872
Link To Document