DocumentCode :
3289282
Title :
Performance tests research of residential central air-conditioning
Author :
Li, Haoxue ; Zhang, Min ; Qi, Xinbo
Author_Institution :
Mech. & Electr. Dept., Henan Mech. & Electr. Eng. Coll., Xinxiang, China
fYear :
2011
fDate :
15-17 April 2011
Firstpage :
1532
Lastpage :
1534
Abstract :
The relations of air-conditioning between daily temperature test results and standard condition test results are researched. Aiming at Xinfei 13.6 kW residential central air-conditioning, the corresponding relations of the unit refrigerant performances between daily temperature and standard condition are made by lots of standard condition test and daily temperature condition tests. The main functions of the unit properties, refrigerant quantity-environment temperature equation, the input power-environment temperature equation and the COP environment temperature equation have been got by regressing the test data using least square method. The figures being analyzed, the concept "The Buffer Refrigerant Temperature" is put forward.
Keywords :
air conditioning; least squares approximations; performance evaluation; refrigerants; COP environment temperature equation; buffer refrigerant temperature; input power-environment temperature equation; least square method; performance tests; power 13.6 kW; refrigerant quantity-environment temperature equation; residential central air conditioning; Central air conditioning; Measurement uncertainty; Refrigerants; Temperature distribution; Temperature measurement; Water heating; Central air-conditioning; Common temperature condition; Residential; Standard condition; Test;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electric Information and Control Engineering (ICEICE), 2011 International Conference on
Conference_Location :
Wuhan
Print_ISBN :
978-1-4244-8036-4
Type :
conf
DOI :
10.1109/ICEICE.2011.5778090
Filename :
5778090