• DocumentCode
    3293387
  • Title

    Accuracy analysis and calibration of a parallel guidance device for minimal invasive spinal surgery

  • Author

    Baoqiang Guo ; Haiyang Jin ; Peng Zhang ; Jianwei Zhang ; Ying Hu ; Hong Zhang

  • Author_Institution
    Guangdong Provincial Key Lab. of Robot. & Intell. Syst., Chinese Univ. of Hong Kong, Shenzhen, China
  • fYear
    2013
  • fDate
    12-14 Dec. 2013
  • Firstpage
    1468
  • Lastpage
    1473
  • Abstract
    In this paper a medical robot based on a 3-RPS parallel platform is presented for providing correct screw path in transpedicular fixation surgery. For improving the accuracy of the robot, a calibration approach for 3-RPS with CMM (Coordinate Measuring Instrument) data is developed. Sensitivity analysis of the error source had been done with Monte-Carlo techniques. The results show that the length errors of the joint-links are main contribution to the output error of the 3-RPS parallel manipulator; and the secondary factor is the radius error of the static and the moving platform. Based on above analysis, the calibration model of the inverse kinematics was established and the mono-branched calibration method was used. The presented method has high identification accuracy for length error of the chain. Based on the identification parameters, the results show that the method can improve the 3-RPS output accuracy.
  • Keywords
    Monte Carlo methods; calibration; coordinate measuring machines; manipulator kinematics; medical robotics; sensitivity analysis; surgery; 3-RPS output accuracy; 3-RPS parallel manipulator; CMM data; Coordinate Measuring Instrument; Monte-Carlo techniques; accuracy analysis; calibration model; chain length error; correct screw path; error source; identification accuracy; identification parameter; inverse kinematics; joint-link; medical robot; minimal invasive spinal surgery; monobranched calibration method; moving platform; output error; parallel guidance device calibration; robot accuracy; secondary factor; sensitivity analysis; static radius error; transpedicular fixation surgery; Accuracy; Bismuth; Calibration; Fasteners; Kinematics; Manipulators; Surgery; Monte-Carlo techniques; accuracy analysis; calibration; parallel manipulator;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Robotics and Biomimetics (ROBIO), 2013 IEEE International Conference on