DocumentCode :
3296013
Title :
MEMS failure analysis case studies using the IR-OBIRCH method - Short circuit localization in a MEMS pressure sensor
Author :
Lellouchi, D. ; Lafontan, X. ; Dhennin, J. ; Beaudoin, F. ; Pressecq, F.
Author_Institution :
NovaMEMS, Ramonville, France
fYear :
2009
fDate :
6-10 July 2009
Firstpage :
827
Lastpage :
831
Abstract :
The use of MEMS is becoming more common in consumer products such as game consoles. But for high reliability domains such as space, there is still a long path. Consequently, the support for process and failure analysis of MEMS devices requires adapted analysis techniques to face growing complexity, reliability and manufacturability challenges. There are already several analysis techniques for micro-electronics components. The goal is to adapt these well known techniques to the failure analysis and characterization of MEMS. In this context a new MEMS failure analysis technique based on thermal laser stimulation has been adapted to characterize short circuit localization in a MEMS pressure sensor.
Keywords :
OBIC; failure analysis; microsensors; pressure sensors; IR-OBIRCH method; MEMS failure analysis; MEMS pressure sensor; microelectronics components; short circuit localization; Circuits; Failure analysis; Laser beams; Laser transitions; Micromechanical devices; Optical beams; Resistance heating; Sensor phenomena and characterization; Thermal resistance; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Physical and Failure Analysis of Integrated Circuits, 2009. IPFA 2009. 16th IEEE International Symposium on the
Conference_Location :
Suzhou, Jiangsu
ISSN :
1946-1542
Print_ISBN :
978-1-4244-3911-9
Electronic_ISBN :
1946-1542
Type :
conf
DOI :
10.1109/IPFA.2009.5232714
Filename :
5232714
Link To Document :
بازگشت