DocumentCode :
3296644
Title :
Dynamic load shedding for shipboard power systems using the non-intrusive load monitor
Author :
Shrestha, Arun ; Foulks, Edward L. ; Cox, Robert W.
Author_Institution :
Dept. of Electr. & Comput. Eng., UNC Charlotte, Charlotte, NC
fYear :
2009
fDate :
20-22 April 2009
Firstpage :
412
Lastpage :
419
Abstract :
This paper presents a dynamic load-shedding scheme that uses a network of non-intrusive load monitors (NILMs). These devices, which can monitor the status of multiple loads using only a single set of aggregate voltage and current transducers, can log important real-time information about individual loads. This information can be used as part of a dynamic load-shedding scheme. The proposed approach is tested using a simulation model constructed in the alternative transients program (ATP). Results demonstrate its effectiveness.
Keywords :
power systems; ships; alternative transients program; current transducers; dynamic load shedding; non-intrusive load monitor; shipboard power systems; voltage transducers; Aggregates; Computerized monitoring; Current measurement; Frequency estimation; Marine vehicles; Power system dynamics; Power systems; Testing; Transducers; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electric Ship Technologies Symposium, 2009. ESTS 2009. IEEE
Conference_Location :
Baltimore, MD
Print_ISBN :
978-1-4244-3438-1
Electronic_ISBN :
978-1-4244-3439-8
Type :
conf
DOI :
10.1109/ESTS.2009.4906545
Filename :
4906545
Link To Document :
بازگشت