DocumentCode
3298164
Title
High resolution and high sensitivity detectors for functional molecular imaging with radionuclides: the role of scintillator pixel size, photodetector anode pitch, collimation technique, and of the readout
Author
Garibaldi, F. ; Accorsi, R. ; Cinti, M.N. ; Cisbani, E. ; Colilli, S. ; Cusanno, F. ; Fratoni, R. ; Giuliani, F. ; Gricia, M. ; Lanza, R.C. ; Lo Meo, S. ; Lucentini, M. ; Majewski, S. ; Pani, R. ; Pellegrini, R. ; Santavenere, F. ; Tsui, B.
Author_Institution
Ist. Superiore di Sanita, Rome
Volume
5
fYear
2005
fDate
23-29 Oct. 2005
Firstpage
2811
Lastpage
2814
Abstract
Good spatial resolution and high sensitivity are required for detectors to be used for most of the bio-medical research and application (small animal imaging, detection of small tumors). In this paper we report on parameter optimization of single photon gamma rays detectors. Simulations and measurements were performed for designing and building detectors for early detection of small tumors in breast and in small animal imaging. Critical parameters are: contrast and signal to noise ratio (SNR). Intrinsic performances (spatial resolution, pixel identification etc.) were optimized first. Arrays of scintillators (NaI(Tl)) of different pixel pitch (down to the present technological limits for NaI(Tl) arrays fabrication (pitch of 2times2 mm2, 1.5times1.5 mm2 and 1.2times1.2 mm2 )) were coupled to arrays of PSPMTs with two anode readout element dimensions (6times6 mm2 and 3times3 mm2). Detectors having field of view of 100times100 mm2 and 150times200 mm2 were designed and built. An electronics system for reading out all the anode pad signals has been designed and constructed. Finally the collimation technique was considered. The limits of the coded aperture option have been studied. Preliminary results of these studies are presented
Keywords
biomedical imaging; gamma-ray apparatus; mammography; nuclear electronics; photodetectors; photomultipliers; position sensitive particle detectors; readout electronics; solid scintillation detectors; tumours; 1.2 mm; 1.5 mm; 100 mm; 150 mm; 2 mm; 200 mm; 3 mm; 6 mm; NaI(Tl) scintillator arrays; anode pad signals; breast tumor detection; collimation technique; electronics system; functional molecular imaging; parameter optimization; photodetector anode pitch; pixel identification; position-sensitive photomultiplier tubes; radionuclides; scintillator pixel size; single photon gamma-ray detectors; small animal imaging; spatial resolution; Animals; Anodes; Biomedical imaging; Collimators; Detectors; Image resolution; Molecular imaging; Photodetectors; Pixel; Spatial resolution;
fLanguage
English
Publisher
ieee
Conference_Titel
Nuclear Science Symposium Conference Record, 2005 IEEE
Conference_Location
Fajardo
ISSN
1095-7863
Print_ISBN
0-7803-9221-3
Type
conf
DOI
10.1109/NSSMIC.2005.1596919
Filename
1596919
Link To Document