  • Title

    High resolution and high sensitivity detectors for functional molecular imaging with radionuclides: the role of scintillator pixel size, photodetector anode pitch, collimation technique, and of the readout

  • Author

    Garibaldi, F. ; Accorsi, R. ; Cinti, M.N. ; Cisbani, E. ; Colilli, S. ; Cusanno, F. ; Fratoni, R. ; Giuliani, F. ; Gricia, M. ; Lanza, R.C. ; Lo Meo, S. ; Lucentini, M. ; Majewski, S. ; Pani, R. ; Pellegrini, R. ; Santavenere, F. ; Tsui, B.

  • Author_Institution
    Ist. Superiore di Sanita, Rome
  • Volume
    5
  • fYear
    2005
  • fDate
    23-29 Oct. 2005
  • Firstpage
    2811
  • Lastpage
    2814
  • Abstract
    Good spatial resolution and high sensitivity are required for detectors to be used for most of the bio-medical research and application (small animal imaging, detection of small tumors). In this paper we report on parameter optimization of single photon gamma rays detectors. Simulations and measurements were performed for designing and building detectors for early detection of small tumors in breast and in small animal imaging. Critical parameters are: contrast and signal to noise ratio (SNR). Intrinsic performances (spatial resolution, pixel identification etc.) were optimized first. Arrays of scintillators (NaI(Tl)) of different pixel pitch (down to the present technological limits for NaI(Tl) arrays fabrication (pitch of 2times2 mm2, 1.5times1.5 mm2 and 1.2times1.2 mm2 )) were coupled to arrays of PSPMTs with two anode readout element dimensions (6times6 mm2 and 3times3 mm2). Detectors having field of view of 100times100 mm2 and 150times200 mm2 were designed and built. An electronics system for reading out all the anode pad signals has been designed and constructed. Finally the collimation technique was considered. The limits of the coded aperture option have been studied. Preliminary results of these studies are presented
  • Keywords
    biomedical imaging; gamma-ray apparatus; mammography; nuclear electronics; photodetectors; photomultipliers; position sensitive particle detectors; readout electronics; solid scintillation detectors; tumours; 1.2 mm; 1.5 mm; 100 mm; 150 mm; 2 mm; 200 mm; 3 mm; 6 mm; NaI(Tl) scintillator arrays; anode pad signals; breast tumor detection; collimation technique; electronics system; functional molecular imaging; parameter optimization; photodetector anode pitch; pixel identification; position-sensitive photomultiplier tubes; radionuclides; scintillator pixel size; single photon gamma-ray detectors; small animal imaging; spatial resolution; Animals; Anodes; Biomedical imaging; Collimators; Detectors; Image resolution; Molecular imaging; Photodetectors; Pixel; Spatial resolution;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record, 2005 IEEE
  • Conference_Location
    Fajardo
  • ISSN
    1095-7863
  • Print_ISBN
    0-7803-9221-3
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2005.1596919
  • Filename
    1596919