• DocumentCode
    3298327
  • Title

    High resolution GSO block detectors using PMT-quadrant-sharing design for human whole body and breast/brain PET applications

  • Author

    Kim, Soonseok ; Wong, Wai-Hoi ; Li, Hongdi ; Zhang, Yuxuan ; Xie, Shuping ; Ramirez, Rocio ; Wang, Yu ; Uribe, Jorge ; Baghaei, Hossain ; Liu, Jiguo ; Liu, Shitao

  • Author_Institution
    M.D. Anderson Cancer Center, Texas Univ., Houston, TX
  • Volume
    5
  • fYear
    2005
  • fDate
    23-29 Oct. 2005
  • Firstpage
    2863
  • Lastpage
    2867
  • Abstract
    High resolution GSO block detectors have been developed using the PMT-quadrant-sharing (PQS) design for human whole body and breast/brain PET applications. Segmented GSO (Ce 0.5 mol%) crystals of 3.02 mmtimes3.02 mmtimes20 mm (13times13 array) and 3.58 mmtimes3.58 mmtimes20 mm (11times11) were assembled together to build two prototype detectors for whole body PET imaging with 39 mm round PMTs and crystals of 2.04 mmtimes2.04 mmtimes20 mm (9times9) for breast/brain PET imaging with 19 mm round PMTs. The enhanced specular reflector (3M Co.) mirror-film windows with reflectance 98% and thickness 0.065 mm were used to control light collection and distribution. Crystal pitches are 3.1 (13times13), 3.64 (11times11), and 2.12 mm (9times9) and crystal-packing fractions are 95, 97, and 93%, respectively. List-mode measurements with Cs-137 sources were carried out to investigate crystal decoding and were analyzed to extract individual crystal spectra. All the crystals in the detectors were identified. Energy resolution for individual crystals ranges from 13.7 to 18.5% (13times13), 12.2 to 14.2% (11times11), and 20.9 to 28.9% (9times9), with overall energy resolutions of 15.6, 13.2, and 24.3%, respectively. Light collection efficiencies for the central crystals are 60 (13times13), 66 (11times11), and 72% (9times9), compared to the corner crystals. The maximum decodable crystals/PMT ratios at 511 keV are high 121-169 for the 39 mm PQS GSO detector design and 81 for the 19 mm PQS GSO detector design with crystals 20 mm deep. It is anticipated that these PQS GSO detectors will provide high resolution and sensitivity at low cost
  • Keywords
    photomultipliers; positron emission tomography; solid scintillation detectors; Cs-137 sources; GSO block detectors; PMT-quadrant-sharing design; brain PET; breast PET; crystal decoding; crystal spectra; enhanced specular reflector mirror-film windows; human whole body PET; light collection efficiencies; segmented GSO crystals; Assembly; Breast; Crystals; Decoding; Detectors; Energy resolution; Humans; Image segmentation; Sensor arrays; Whole-body PET;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record, 2005 IEEE
  • Conference_Location
    Fajardo
  • ISSN
    1095-7863
  • Print_ISBN
    0-7803-9221-3
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2005.1596929
  • Filename
    1596929