    Validity analysis of dynamic electrocardiogram waveform selection strategy by waveform pattern comparison

  • Author

    Zheng, Gang ; Yu, Tian ; Cao, Guo C.

  • Author_Institution
    Sch. of Comput. & Commun. Eng., Tianjin Univ. of Technol., Tianjin
  • fYear
    2009
  • fDate
    9-11 April 2009
  • Firstpage
    1
  • Lastpage
    4
  • Abstract
    In the paper, a evaluation method was introduced in electrocardiogram (ECG) waveform validity analysis. The method is ECG waveform pattern comparison. The evaluation work was done on a dynamic ECG waveform selection. It is very important to get the real accurate of the selection strategy. The pattern comparison method gives the method, result, and analysis on ECG waveform selection effect. The accurate can reach 96%. And the method can be process on all the ECG waveforms which as preprocessed by the strategy used in the paper.
  • Keywords
    electrocardiography; statistical analysis; waveform analysis; ECG waveform pattern comparison; dynamic ECG waveform selection; electrocardiogram; Cardiac disease; Detection algorithms; Educational technology; Electrocardiography; Filtering; Heart rate; Morphology; Nonlinear filters; Pattern analysis; Shape;