• DocumentCode
    3298798
  • Title

    The Soil Temperature Restoration Characteristic of Hybrid Ground Source Heat Pump in the Intermittent Performance Condition

  • Author

    Wang, Jinggang ; Du, MeiXia ; Zhao, Jin ; Chi, Yuxia

  • Author_Institution
    Coll. of Urban Constr., Hebei Univ. of Eng., Handan, China
  • fYear
    2009
  • fDate
    11-12 July 2009
  • Firstpage
    511
  • Lastpage
    513
  • Abstract
    The soil temperature restoration characteristic has an important effect on ground source heat pump. The cooling tower would be used to reduce the soil temperature at night when the heat pump unit was shut down of a hybrid ground source heat pump. The ground soil temperature restoration information had been measured for 10 days, and the results were analyzed.
  • Keywords
    cooling towers; heat pumps; soil; cooling tower; hybrid ground source heat pump; intermittent performance condition; soil temperature restoration; time 10 day; Air conditioning; Cooling; Educational institutions; Geologic measurements; Heat engines; Heat pumps; Land surface temperature; Soil measurements; Temperature measurement; Water heating; intermittent performence; supplemental cooling system; the ground soil temporature restoration;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Services Science, Management and Engineering, 2009. SSME '09. IITA International Conference on
  • Conference_Location
    Zhangjiajie
  • Print_ISBN
    978-0-7695-3729-0
  • Type

    conf

  • DOI
    10.1109/SSME.2009.87
  • Filename
    5233236