• DocumentCode
    3302593
  • Title

    Estimating the heat losses from a laboratory pilot plant for CO2 absorption

  • Author

    Owrang, Farshid ; Svendsen, Hallvard F.

  • Author_Institution
    Dept. of Chem. Eng., Norwegian Univ. of Sci. & Technol., Trondheim, Norway
  • fYear
    2010
  • fDate
    2-4 Nov. 2010
  • Firstpage
    180
  • Lastpage
    183
  • Abstract
    The heat loss of a CO2 laboratory pilot plant was estimated at different water mass flow circulation rates and reboiler duties. The results indicate that the heat loss increases with increasing water mass flow rate. The reboiler duty did not significantly affect the heat lost to the ambient air during the experiment. The maximum heat loss of the entire plant was estimated to be about 4.1 kW at a reboiler duty of about 6.1 kW when the water mass flow rate was about 454 kg/h.
  • Keywords
    absorption; boilers; carbon compounds; heat losses; CO2; carbon dioxide absorption; heat loss estimation; laboratory pilot plant; reboiler duty; water mass flow circulation rates; Heat pumps; Heating; ISO standards; Laboratories; Monitoring; Temperature measurement; Temperature sensors;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Chemical, Biological and Environmental Engineering (ICBEE), 2010 2nd International Conference on
  • Conference_Location
    Cairo
  • Print_ISBN
    978-1-4244-8748-6
  • Electronic_ISBN
    978-1-4244-8749-3
  • Type

    conf

  • DOI
    10.1109/ICBEE.2010.5649674
  • Filename
    5649674