DocumentCode :
3302815
Title :
Fault-tolerant strategy using neutral-shift method for cascaded multilevel inverters based on level-shifted PWM
Author :
Seok-Min Kim ; June-Seok Lee ; Kyo-Beum Lee
Author_Institution :
Dept. of Space Survey Inf. Technol., Ajou Univ., Suwon, South Korea
fYear :
2015
fDate :
1-5 June 2015
Firstpage :
1327
Lastpage :
1332
Abstract :
Most proposed methods for a fault-tolerant operation in many of studies are based on a phase-shifted PWM (PS-PWM) method. However these methods are not applied directly to multilevel inverter systems using a level-shifted PWM (LS-PWM). This paper focuses on fault-tolerant operation for a cascaded multilevel inverter based on LS-PWM. During the occurrence of a single-inverter-cell fault, reconfiguration of the carrier bands scheme is implemented and modulation assignment of inverter cells is modified in this proposed fault-tolerant operation. It is possible to generate balanced three-phase line-to-line voltages and line currents with the proposed strategy when a device failure occurs in cascaded multilevel inverters using LS-PWM. The feasibility of the proposed method is proved by simulation results.
Keywords :
PWM invertors; fault tolerance; LS-PWM; PS-PWM method; carrier bands scheme; fault-tolerant strategy; level-shifted PWM; multilevel inverter systems; neutral-shift method; phase-shifted PWM method; single-inverter-cell fault; Asia; Fault-tolerance; Level-Shifted pulsewidth modulation (PWM) strategies; Multilevel inverters; Neutral shift;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Power Electronics and ECCE Asia (ICPE-ECCE Asia), 2015 9th International Conference on
Conference_Location :
Seoul
Type :
conf
DOI :
10.1109/ICPE.2015.7167951
Filename :
7167951