Title :
Analysis of Factors Influencing Measurement Accuracy of Spinneret Automatic Inspection System
Author :
Yang, Chongchang ; Li, Chunlei ; Cui, Bin
Author_Institution :
Coll. of Mech. Eng., Donghua Univ., Shanghai, China
Abstract :
By using orthogonal test method, this paper studies several influential factors, such as the optic magnification of the system, the intensity of backlight and so on, which influence the measurement accuracy of the spinneret automatic inspection system based on machine vision. Through range and variance analysis, the paper determines the best inspecting condition of the inspection system and finds out the factors that have significant effect to measurement accuracy of machine vision system. At the same time, the paper looks out some ways to improve the measurement accuracy of the spinneret automatic inspection system.
Keywords :
Analysis of variance; Automatic optical inspection; Automatic testing; Charge coupled devices; Focusing; Lenses; Machine vision; Man machine systems; Mechanical variables measurement; System testing; Orthogonal test method; machine vision; measurement accuracy; range analysis; variance analysis;
Conference_Titel :
Machine Vision and Human-Machine Interface (MVHI), 2010 International Conference on
Conference_Location :
Kaifeng, China
Print_ISBN :
978-1-4244-6595-8
Electronic_ISBN :
978-1-4244-6596-5
DOI :
10.1109/MVHI.2010.63