DocumentCode :
3307288
Title :
Junction temperature estimation for an advanced active power cycling test
Author :
Choi, U.M. ; Blaabjerg, F. ; Jorgensen, S.
Author_Institution :
Dept. of Energy Technol., Aalborg Univ., Aalborg, Denmark
fYear :
2015
fDate :
1-5 June 2015
Firstpage :
2944
Lastpage :
2950
Abstract :
On-state collector-emitter voltage (VCE) is a good indicator to determine the wear-out condition of power device modules. Further, it is a one of the Temperature Sensitive Electrical Parameters (TSEPs) and thus can be used for junction temperature estimation. In this paper, the junction temperature estimation method using on-state VCE for an advanced active power cycling test is proposed. The concept of the advanced power cycling test is explained first. Afterwards the junction temperature estimation method using on-state VCE and current is presented. Further, the method to improve the accuracy of the maximum junction temperature estimation is also proposed. Finally, the validity and effectiveness of the proposed method is confirmed by experimental results.
Keywords :
estimation theory; power electronics; temperature measurement; TSEP; advanced active power cycling test; junction temperature estimation method; maximum junction temperature estimation; on-state VCE; on-state collector-emitter voltage; power device modules; temperature sensitive electrical parameters; wear-out condition; Current measurement; Estimation; Junctions; Temperature; Temperature measurement; Temperature sensors; Voltage measurement; Power cycling test; TSEP; junction temperature estimation; power device module;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Power Electronics and ECCE Asia (ICPE-ECCE Asia), 2015 9th International Conference on
Conference_Location :
Seoul
Type :
conf
DOI :
10.1109/ICPE.2015.7168194
Filename :
7168194
Link To Document :
بازگشت