DocumentCode :
3308538
Title :
Edge guided delineation of the prostate in transrectal ultrasound images
Author :
Path, S.D. ; Chalana, V. ; Haynor, D.R. ; Kim, Youngjae
Author_Institution :
Dept. for Bioeng., Washington Univ., Seattle, WA, USA
Volume :
2
fYear :
1999
fDate :
36434
Abstract :
Prostate boundaries form the basis of many diagnosis/treatment procedures for prostate diseases. In this paper, a new paradigm of edge guidance is described that involves just-enough-interaction with the expert, leading to robust delineation of the prostate boundaries. We statistically show that an increase in the consistency and the accuracy of prostate delineation is achieved using the edges as visual guide
Keywords :
biological organs; biomedical ultrasonics; edge detection; image enhancement; image segmentation; medical expert systems; medical image processing; surface fitting; Canny edge detector; contrast enhancement; deformable membrane fitting; deformable surface fitting; edge guided delineation; just-enough-interaction with expert; knowledge based filtering; prostate boundaries; robust delineation; segmentation evaluation; speckle reduction; sticks-enhanced image; transrectal ultrasound images; visual guide; Biomedical engineering; Biomembranes; Diseases; Image edge detection; Image segmentation; Joining processes; Robustness; Speckle; Surface fitting; Ultrasonic imaging;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
[Engineering in Medicine and Biology, 1999. 21st Annual Conference and the 1999 Annual Fall Meetring of the Biomedical Engineering Society] BMES/EMBS Conference, 1999. Proceedings of the First Joint
Conference_Location :
Atlanta, GA
ISSN :
1094-687X
Print_ISBN :
0-7803-5674-8
Type :
conf
DOI :
10.1109/IEMBS.1999.804212
Filename :
804212
Link To Document :