DocumentCode :
3308970
Title :
Investigation of alternating and continuous functional MRI experimental designs at 1.5 T
Author :
Mohamed, F.B. ; Tracy, J.I. ; Faro, S.H. ; Koenigsberg, R. ; Emperado, J. ; Pinus, A.
Author_Institution :
Dept. of Radiol., MCP Hahnemann Univ., Philadelphia, PA, USA
Volume :
2
fYear :
1999
fDate :
36434
Abstract :
Studies the effect of two different functional MRI (fMRI) experimental design parameters on blood oxygenation level dependent (BOLD) signal contrast. The design parameters examined were: (1) the pattern of administering the control and activation conditions; and (2) the quantity of the control signals collected. Six normal volunteers underwent single finger opposition fMRI using T2*-weighted echo planar imaging technique. The BOLD signal contrast was evaluated using analysis of variance on normalized t-values and mean region-of-interest (ROI) intensity. The results demonstrate: (1) the alternating pattern of administering rest and activation epochs produced a more robust statistical difference in BOLD signal than a continuous pattern, and (2) a reduction in the amount of rest signal collected did not result in a statistically significant reduction in the BOLD signal. The results indicate that manipulating such factors of signal collection does alter BOLD signal properties
Keywords :
biomedical MRI; brain; design of experiments; medical image processing; 1.5 T; T2*-weighted echo planar imaging technique; activation conditions; activation epochs; alternating functional MRI experimental designs; alternating pattern; analysis of variance; blood oxygenation level dependent signal contrast; continuous functional MRI experimental designs; control signals; design parameters; mean region-of-interest intensity; normal volunteers; normalized t-values; rest epochs; robust statistical difference; single finger opposition functional magnetic resonance imaging; Analysis of variance; Biomedical engineering; Blood; Design for experiments; Fingers; Magnetic resonance imaging; Radiology; Statistical analysis; Statistics; Testing;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
[Engineering in Medicine and Biology, 1999. 21st Annual Conference and the 1999 Annual Fall Meetring of the Biomedical Engineering Society] BMES/EMBS Conference, 1999. Proceedings of the First Joint
Conference_Location :
Atlanta, GA
ISSN :
1094-687X
Print_ISBN :
0-7803-5674-8
Type :
conf
DOI :
10.1109/IEMBS.1999.804243
Filename :
804243
Link To Document :
بازگشت