DocumentCode
330928
Title
Clinical validation of an automated boundary tracking algorithm using cardiac MR images
Author
Latson, LA ; Powell, KA ; Sturm, B. ; White, RD
Author_Institution
Whitaker Biomed. Imaging Lab., Cleveland Clinic Found., OH, USA
fYear
1998
fDate
13-16 Sep 1998
Firstpage
741
Lastpage
744
Abstract
Manual tracing of ventricular borders in MRI images is a tedious process. The goal of this research was to develop an algorithm for tracking the borders of the left ventricle (LV) in a cine-MRI gradient-echo temporal data set. The algorithm was validated on healthy volunteers and patients with dilated cardiomyopathy (DCM) before and after surgical remodeling of the LV. A full tomographic set (~11 slices/case) of short axis images were obtained through systole. Initial endocardial and epicardial contours for the end-diastolic (ED) and end-systolic (ES) phases were manually traced on the computer by an expert. The initial tracing of the ED borders were used as starting point. These borders were then temporally tracked through each phase of the temporal data set, until the ES phase was reached (~7 phases/slice). Peak gradients along equally spaced chords calculated perpendicular to centerline determined midway between the endocardial and epicardial borders were used for border detection. This approach was tested by comparing the LV epicardial and endocardial volumes calculated at ES to those based on the tracings by an expert. The LV volumes based on the borders obtained from the automated algorithm correlated well with those calculated from the expert manual tracings
Keywords
angiocardiography; biomedical MRI; image segmentation; medical image processing; surface fitting; tracking filters; automated boundary tracking algorithm; cardiac MRI images; cine-MRI gradient-echo temporal data set; clinical validation; contour tracking; dilated cardiomyopathy; end-diastolic phase; end-systolic phase; endocardial contours; endocardial volumes; epicardial contours; epicardial volumes; equally spaced chords; full tomographic set; left ventricle borders; outlines filtering; peak gradients; short axis images; surgical remodeling; Biomedical engineering; Biomedical imaging; Blood; Cardiology; Laboratories; Magnetic resonance imaging; Morphology; Radiology; Testing; Tomography;
fLanguage
English
Publisher
ieee
Conference_Titel
Computers in Cardiology 1998
Conference_Location
Cleveland, OH
ISSN
0276-6547
Print_ISBN
0-7803-5200-9
Type
conf
DOI
10.1109/CIC.1998.731980
Filename
731980
Link To Document