DocumentCode :
3309636
Title :
Subband denoising technique for high noise PET image analysis
Author :
Lin, Hong-Dun ; Lin, Kang-Ping ; Yu, Chin-Lung ; Wu, Liang-Chih ; Liu, Ren-Shyan
Author_Institution :
Dept. of Electr. Eng., Chung-Yuan Univ., Chung-Li, Taiwan
Volume :
2
fYear :
1999
fDate :
36434
Abstract :
To improve the high noise problem for a PET image is important work because the quality of the PET image and the diagnosis accuracy is affected by this noise. For this reason, a novel subband denoising technique is provided. The method is based on subband transformation and a statistical method. By using the technique the noise can be inhibited effectively
Keywords :
medical image processing; noise; positron emission tomography; statistical analysis; diagnosis accuracy; high noise PET image analysis; quality; statistical method; subband denoising technique; subband transformation; Clinical diagnosis; Frequency; Image analysis; Imaging phantoms; Lighting; Noise level; Noise measurement; Noise reduction; Positron emission tomography; Statistical analysis;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
[Engineering in Medicine and Biology, 1999. 21st Annual Conference and the 1999 Annual Fall Meetring of the Biomedical Engineering Society] BMES/EMBS Conference, 1999. Proceedings of the First Joint
Conference_Location :
Atlanta, GA
ISSN :
1094-687X
Print_ISBN :
0-7803-5674-8
Type :
conf
DOI :
10.1109/IEMBS.1999.804287
Filename :
804287
Link To Document :
بازگشت