DocumentCode :
3322338
Title :
Notice of Retraction
Finite Element Analysis of Stent Deployment in a Stenotic Artery and Their Interactions
Author :
Zhao, S. ; Linxia Gu ; Froemming, S.R. ; Hammel, J.M. ; Lang, H.
Author_Institution :
Dept. of Mech. Eng., Univ. of Nebraska-Lincoln, Lincoln, NE, USA
fYear :
2011
fDate :
10-12 May 2011
Firstpage :
1
Lastpage :
4
Abstract :
Notice of Retraction

After careful and considered review of the content of this paper by a duly constituted expert committee, this paper has been found to be in violation of IEEE´s Publication Principles.

We hereby retract the content of this paper. Reasonable effort should be made to remove all past references to this paper.

The presenting author of this paper has the option to appeal this decision by contacting TPII@ieee.org.

In this study, a nonlinear finite element analysis was implemented on the balloon-expandable stent deployment in stenotic artery with asymmetric plaque to investigate the stent stenotic artery interaction. Uniform pressure loading was applied onto the inner surface of stent to expand it. The result showed that the stent restores the patency of the stenotic artery lumen; however, non-uniform expansion (i.e. dogbone shape) was observed on stent, which indicates a possibility of the injury to arterial wall at the ends of stent. The stress on arterial wall induced by stent expansion is higher than blood pressure induced stress, which may initiate the proliferation of smooth muscle cells and lead to the restenosis. The stent design was alternated by increasing the thickness of distal strut. With this improved design, the dogboning effect was alleviated dramatically and stress level on arterial wall was also decreased. This FEM work provided a better understanding of the coronary stenting and its effect on the arterial response from biomechanical view, which can facilitate new stent design.
Keywords :
biomechanics; blood; blood vessels; cellular biophysics; finite element analysis; injuries; muscle; FEM; arterial wall; asymmetric plaque; balloon-expandable stent deployment; biomechanics; blood pressure-induced stress; coronary stenting; distal strut; dogboning effect; injury; nonlinear finite element analysis; smooth muscle cells; stenotic artery lumen; stent-stenotic artery interaction; stress level; uniform pressure loading; Arteries; Finite element methods; Injuries; Materials; Shape; Stress; USA Councils;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Bioinformatics and Biomedical Engineering, (iCBBE) 2011 5th International Conference on
Conference_Location :
Wuhan
ISSN :
2151-7614
Print_ISBN :
978-1-4244-5088-6
Type :
conf
DOI :
10.1109/icbbe.2011.5780291
Filename :
5780291
Link To Document :
بازگشت