DocumentCode :
332376
Title :
Breakdown time of triggered vacuum gap
Author :
Wang, Y. ; Wang, Y.X. ; Li, Y.L.
Author_Institution :
Dept. of Electromagn. Eng., Dalian Univ. of Technol., China
Volume :
1
fYear :
1998
fDate :
17-21 Aug 1998
Firstpage :
130
Abstract :
The breakdown time of a triggered vacuum gap (TVG) is inversely proportional to the triggering energy. Because of the equivalent inductance increase, the breakdown time trends a constant, after the triggering energy reaches a certain value. With the use of a low inductance capacitor, a reduced triggering energy can result in a remarkable decrease of the breakdown time. The improvement in the structure of the TVG is a good way of reducing the breakdown time
Keywords :
capacitors; electrodes; inductance; insulation testing; vacuum breakdown; vacuum insulation; breakdown time; equivalent inductance; low inductance capacitor; structure improvement; triggered vacuum gap; triggering energy; Breakdown voltage; Capacitance; Capacitors; Electric breakdown; Electron tubes; Frequency; Inductance; Insulation; Production facilities; Vacuum breakdown;
fLanguage :
English