DocumentCode :
3324024
Title :
Thermal Lensing Spectroscopy Analysis of Er:YAG Crystal Rod: Thermal Focal Length Measure
Author :
Hu Ting ; Wang Fu ; Ye Bing ; Xin Yun
Author_Institution :
Sch. of Electron. Sci. & Phys., HeFei Univ. of Technol., Hefei, China
fYear :
2011
fDate :
16-18 May 2011
Firstpage :
1
Lastpage :
3
Abstract :
The output efficiency of Er: YAG laser is low and thermal lens effect is apparent, so it brings about great affection on quality and stability of light beam. This article has given a simple method to survey thermal lens focal length, which use CCD vidicon to extract facula data in order to fitting Gaussian beam, and then calculate equivalent thermal focal length according to changes of Gauss beam. Experiment results show that thermal lens also makes extensive effect in low-power, and if higher the pumping power, smaller the thermal focal length. The results of experiment in accordant with that of theory.
Keywords :
CCD image sensors; erbium; laser beams; optical pumping; solid lasers; thermal lensing; CCD vidicon; Er:YAG crystal rod; Gaussian beam; YAG:Er; equivalent thermal focal length; facula data extract; pumping power; thermal lens focal length; thermal lensing spectroscopy; Crystals; Laser beams; Laser theory; Lenses; Measurement by laser beam; Surface emitting lasers; Thermal lensing;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Photonics and Optoelectronics (SOPO), 2011 Symposium on
Conference_Location :
Wuhan
ISSN :
2156-8464
Print_ISBN :
978-1-4244-6555-2
Type :
conf
DOI :
10.1109/SOPO.2011.5780383