    Effect of Tissue in HIFU Beam Pathway on Ultrasound Propagation

  • Author

    Li, Faqi ; Wang, Bin ; Ai, Huijian ; Wang, Zhibiao ; Gong, Xiaobo

  • Author_Institution
    Dept. of Biomed. Eng., Chongqing Med. Univ., Chongqing, China
  • fYear
    2011
  • fDate
    10-12 May 2011
  • Firstpage
    1
  • Lastpage
    3
  • Abstract
    In HIFU therapy, it is very important to determine the ultrasound attenuation of different tissue from skin to target in HIFU beampath for predicting in advance the dose. So the reduction in acoustic radiation force in the presence of different tissue in HIFU beampath has been studied by a radiation force method. At a room temperature 20°C, the acoustic radiation force in the presence and absence of the prepared different tissue such as bovine liver of various thickness, skin, intercostal tissue closed to liver (including skin, fat, intercostal muscle, ribs and parietal pleura) and ribs in front of absorber in degassed water was measured at same acoustic power at transducer surface. Then the ratio of radiation force in the presence of different tissue relative to degassed water in HIFU beampath and the ultrasound attenuation were calculated. The ratio of radiation force in the presence of skin, intercostal tissue and ribs of pig relative to degassed water in HIFU beampath was 10%, 85.5% and 57.5% respectively. The ultrasound attenuation coefficient α in bovine liver was shown to be frequency f dependent, fitting the equation as follows α=0.43f1.05 [dB.cm-1.s1.05]. The results showed that the ultrasound energy was attenuated markedly when HIFU traveled through intercostal tissue, especially ribs in HIFU beampath. This work offered experimental data that should be useful for future HIFU dosage studies.
  • Keywords
    biological tissues; biomedical measurement; dosimetry; liver; ultrasonic propagation; ultrasonic therapy; HIFU dosage; HIFU therapy; Haifu Focused Ultrasound Tumor Therapeutic System; acoustic power; acoustic radiation force; bovine liver; degassed water; high intensity focused ultrasound; intercostal tissue; parietal pleura; ribs; skin; temperature 20 degC; ultrasound attenuation; ultrasound propagation; Acoustics; Attenuation; Force; Liver; Ribs; Skin; Ultrasonic imaging;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Bioinformatics and Biomedical Engineering, (iCBBE) 2011 5th International Conference on
  • Conference_Location
    Wuhan
  • ISSN
    2151-7614
  • Print_ISBN
    978-1-4244-5088-6
  • Type

    conf

  • DOI
    10.1109/icbbe.2011.5780421
  • Filename
    5780421