    Traditional autoradiography is an imaging modality used in life sciences where thin ex-vivo tissue sections are placed in direct contact with autoradiographic film. High resolution autoradiograms can be obtained using low energy radioisotopes, such as 3H where an intrinsic 0.1-1 ¿m spatial resolution can be achieved due to limited ß-path length. Several digital alternatives have been presented in recent years to replace conventional film as the imaging medium, but the spatial resolution of film remains unmatched. Although silicon-based imaging technologies have demonstrated higher sensitivity compared to conventional film, the main issue that remains is spatial resolution. We address this here with an investigation into the design parameters that impact on spatial resolution when imaging uncollimated ß-found in autoradiography. The study considers Monte Carlo simulation of the energy deposition process, the charge diffusion process in silicon and the detector noise, and this is applied to a range of radioisotope ß energies typically used in autoradiography. Finally an optimal detector geometry to obtain the best possible spatial resolution for a specific technology and a specific radioisotope is suggested.
  • Keywords
    CCD image sensors; CMOS image sensors; Monte Carlo methods; biomedical imaging; radioisotope imaging; radioisotopes; silicon radiation detectors; Monte Carlo simulation; autoradiographic film; autoradiography; charge diffusion process; energy deposition process; low energy radioisotopes; radioisotope beta energies; silicon-based detectors; spatial resolution; thin ex-vivo tissue sections; uncollimated beta particles; Detectors; Diffusion processes; Energy resolution; Geometry; High-resolution imaging; Monte Carlo methods; Radioactive materials; Semiconductor films; Silicon; Spatial resolution; CCD; CMOS; Digital Autoradiography; Geant4; Spatial Resolution;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record (NSS/MIC), 2009 IEEE
  • Conference_Location
    Orlando, FL
  • ISSN
    1095-7863
  • Print_ISBN
    978-1-4244-3961-4
  • Electronic_ISBN
    1095-7863
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2009.5401625
  • Filename
    5401625