    Pulsating parameter method for fault diagnosis for a hydraulic pump

  • Author

    Liu, Silan ; Hung, James C.

  • Author_Institution
    Dept. of Hydraulic Syst. Developing, Zhongshan Stone General M. & E. Co., China
  • fYear
    1991
  • fDate
    28 Oct-1 Nov 1991
  • Firstpage
    2145
  • Abstract
    The authors present the pulsating parameter method in the frequency domain using two parameters of the pulsating model of an axial piston pump as major monitoring parameters to diagnose the fault of the pump. In order to apply the theory of transmission in a hydraulic pipeline to identify the model, a whole set of algorithms is also developed. Compared with existing methods, this method is much easier and cheaper to apply to hydraulic systems, less affected by the conditions of the environment, less sensitive to the errors in signal detection and data processing, and more sensitive to the faults of the pump
  • Keywords
    failure analysis; frequency-domain analysis; hydraulic control equipment; pumps; axial piston pump; data processing errors; fault diagnosis; frequency domain; hydraulic pipeline; hydraulic pump; pulsating parameter method; signal detection errors; Cities and towns; Condition monitoring; Employee welfare; Equations; Fault diagnosis; Frequency domain analysis; Hydraulic systems; Pipelines; Pistons; Signal processing;