DocumentCode :
3326519
Title :
Small animal optical multispectral Cerenkov tomography
Author :
Spinelli, Antonello E. ; Kuo, Chaincy ; Rice, Brad W. ; Calandrino, Riccardo ; Marzola, Pas Quina ; Sbarbati, Andrea ; Boschi, Federico
Author_Institution :
Med. Phys. Dept., San Raffaele Sci. Inst., Milan, Italy
fYear :
2011
fDate :
23-29 Oct. 2011
Firstpage :
4462
Lastpage :
4466
Abstract :
A novel pre-clinical imaging modality called Cerenkov luminescence imaging (CLI) has been recently introduced for small animals in vivo imaging. CLI is based on the detection of optical Cerenkov radiation generated by beta particles as they travel into the animal tissues with energy greater than Cerenkov threshold. The main goal of this work is the development of a novel optical image reconstruction method called multi spectral Cerenkov luminescence tomography (msCLT). The starting point of the msCLT reconstruction scheme is a set of 2D planar images acquired using several narrow bandpass filters. Because of the different tissues absorption at different wavelengths this provide distinctive information content that can be used for image reconstruction. More precisely the msCLT algorithm is based on a regularized iterative non-negative scheme in order to find the unknown source intensity solution, the theoretical Cerenkov emission spectrum was also included in the algorithm. In order to investigate the performances of the msCLT approach in vitro and in vivo imaging using 32P-ATP were performed by using the IVIS 200 (Caliper, a PerkinElmer company). A set of spatial resolution measurements were performed using a small capillary source placed between several slices of chicken breast at different depths. The spatial resolution obtained from the msCLT reconstructed images of the capillary showed that the FWHM is 1.5 mm for a source placed at 6 mm depth. In order to investigate the in vivo performances of the msCLT reconstruction method, a control nude mice injected with 10 MBq of 32P-ATP were imaged. Whole body MRI was acquired to provide an anatomical localization of the Cerenkov emission. msCLT reconstructed images co-registered with MRI images showed that the Cerenkov emission regions matches well with anatomical regions, such as the brain, heart and abdomen. These results were also confirmed by ex vivo imaging of organs such as intestine, brain, heart and - ibs.
Keywords :
Cherenkov counters; band-pass filters; biological tissues; biomedical MRI; biomedical optical imaging; brain; cardiology; image reconstruction; image registration; image resolution; iterative methods; luminescence; medical image processing; optical tomography; radiation detection; 2D planar image analysis; 32P-ATP; Cerenkov emission region; Cerenkov emission spectrum; Cerenkov luminescence imaging; MRI image; VIS 200; abdomen; anatomical localization analysis; anatomical regions; animal optical multispectral Cerenkov tomography; animal tissues; brain; capillary source; chicken breast; depth 6 mm; exvivo imaging method; heart; image coregistration; intestine; multispectral Cerenkov luminescence tomography; narrow bandpass filters; optical Cerenkov radiation detection; optical image reconstruction method; preclinical imaging modality; regularized iterative nonnegative scheme; ribs; spatial resolution measurement method; tissues absorption analysis; Biomedical imaging; Image reconstruction; Image resolution; Positron emission tomography; Ribs; Single photon emission computed tomography;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2011 IEEE
Conference_Location :
Valencia
ISSN :
1082-3654
Print_ISBN :
978-1-4673-0118-3
Type :
conf
DOI :
10.1109/NSSMIC.2011.6152495
Filename :
6152495
Link To Document :
بازگشت