• DocumentCode
    3326827
  • Title

    Assessment of the effect of 3D resolution recovery during SPECT image reconstruction on quantification of small liver tumors: A simulation study

  • Author

    Kalantari, Faraz ; Rajabi, Hossein ; Saghari, Mohsen ; Ardekani, Alireza Emami

  • Author_Institution
    Dept. of Med. Phys., Tarbiat Modares Univ., Tehran, Iran
  • fYear
    2011
  • fDate
    23-29 Oct. 2011
  • Firstpage
    2891
  • Lastpage
    2894
  • Abstract
    Non ideal collimation and detector blurring are the main causes of resolution loss in single photon computed tomography (SPECT) that affect both qualitative and quantitative interpretation of SPECT images. In this research we evaluate the importance of resolution recovery in determining the absolute amount of activity in small liver tumors by comparing three different approaches: ordered subsets expectation maximization (OSEM), OSEM with 2D resolution recovery and OSEM with 3D resolution recovery. Two different sets of projections were created. Model based projections were created by layer by layer blurring of activity phantom using known distance dependent Gaussian functions. Simple ray sum of this blurred phantom was driven to create projections. This simulates noise free projections with completely known system response. The other set of projections was created using SIMIND Monte Carlo simulator. Eight small tumors (1×1×1 cm) were considered on different parts of NCAT liver phantom in such a way that all appear in same plane in a sagittal slice. Vertical distance between each couple of tumors was varied between 1 and 4 pixels (equal to 3.3 and 13.3 mm). To evaluate the value of resolution recovery during reconstruction, OSEM with the ability of modeling both 2D and 3D system response model during reconstruction was developed and used. Both 2D and 3D resolution recovery results in better quantitative results compared to simple OSEM. 3D resolution recovery, however reconstruct images with much higher quantitative accuracy. Only in 3D resolution recovery it is possible to separate all couple of tumors in axial direction. The amount of activity recovery depends on the number of iteration. Using 8 iterations and 8 subsets in each iteration, 3D resolution recovery results in 8% better activity recovery compared to 2D and 13% compared to simple OSEM. This amount is 27% and 46% for 25 iterations.
  • Keywords
    expectation-maximisation algorithm; image reconstruction; image resolution; liver; medical image processing; phantoms; single photon emission computed tomography; tumours; 2D resolution recovery; 3D resolution recovery; Gaussian functions; OSEM; SIMIND Monte Carlo simulator; SPECT; image reconstruction; ordered subsets expectation maximization; phantom; single photon computed tomography; small liver tumors; Biomedical imaging; Image resolution; Monte Carlo methods; Single photon emission computed tomography; Solid modeling; Three dimensional displays; Tumors;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2011 IEEE
  • Conference_Location
    Valencia
  • ISSN
    1082-3654
  • Print_ISBN
    978-1-4673-0118-3
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2011.6152512
  • Filename
    6152512