Title :
CLOSY: A very precise clock generation for timing measurements and synchronization of the CBM ToF wall
Author_Institution :
EE-Dept., GSI Helmholtzzentrum fur Schwerionenforschung GmbH, Darmstadt, Germany
fDate :
Oct. 24 2009-Nov. 1 2009
Abstract :
A new electronics for precise clock generation and distribution has been designed for the CBM ToF-wall. The main card (CBM-CLOCK-SYTEM) is based on a frequency synthesizer chip to create two independent output frequencies that are phase coupled. An additionally downstream fast CPLD creates a synchronization signal, which is needed as a periodically epoch marker for the system.
Keywords :
clock distribution networks; nuclear electronics; programmable logic devices; synchronisation; timing circuits; CBM ToF wall; CBM-clock-sytem; CLOSY; CPLD; clock distribution; clock generation; frequency synthesizer chip; output frequencies; periodically epoch marker; synchronization signal; timing measurements; Clocks; Frequency synchronization; Frequency synthesizers; Instruments; Jitter; Nuclear power generation; Oscillators; Switches; Temperature sensors; Timing;
Conference_Titel :
Nuclear Science Symposium Conference Record (NSS/MIC), 2009 IEEE
Conference_Location :
Orlando, FL
Print_ISBN :
978-1-4244-3961-4
Electronic_ISBN :
1095-7863
DOI :
10.1109/NSSMIC.2009.5401720