• DocumentCode
    3327104
  • Title

    Interpolation for the gap-filling of the HRRT PET sinograms by using the slices in the direction of the radial samples

  • Author

    Tuna, Uygar ; Peltonen, Sari ; Ruotsalainen, Ulla

  • Author_Institution
    Dept. of Signal Process., Tampere Univ. of Technol., Tampere, Finland
  • fYear
    2009
  • fDate
    Oct. 24 2009-Nov. 1 2009
  • Firstpage
    3273
  • Lastpage
    3279
  • Abstract
    The ECAT High Resolution Research Tomograph (HRRT) (CTI PET Systems, Knoxville, TN, USA) is the state-of-the-art positron emission tomography (PET) scanner in the nuclear medicine imaging field. The gantry of the HRRT PET scanner has detector-free regions. These regions between the detector blocks introduce missing parts to the acquired PET data. Without the estimation of the missing parts of the sinogram data, the methods which require full sinogram dataset give undesired results. Previously, we proposed the iterative discrete cosine transform (DCT) domain gap-filling method which gave better quantitative and visual results than the previously published gap-filling methods. The gap-filling methods published so far estimate the missing parts only on the transaxial slices while they are ignoring the information from the neighboring transaxial slices. In this study, we propose a non-iterative gap-filling method for the compensation of the HRRT PET sinogram data by using the slices in the direction of radial samples. We compared the results of this new method with the results of the improved version of the DCT domain gap-filling approach. We used 3D numerical phantom sinogram at eight different Poisson noise levels for checking the regional quantitative results. For visual assessment, we employed a [11C]-raclopride human brain study. After the missing parts were estimated, we applied 2D filtered backprojection which obligates full sinogram dataset. The results showed that the non-iterative interpolation by using the slices in the direction of radial samples gave similar results as the DCT domain data estimation method. Its simplicity and the short processing time over the DCT domain gap-filling method are the notable advantageous properties of this non-iterative gap-filling approach.
  • Keywords
    brain; discrete cosine transforms; interpolation; medical image processing; positron emission tomography; 2D filtered backprojection; 3D numerical phantom sinogram; ECAT High Resolution Research Tomograph; HRRT PET sinograms; Poisson noise level; gap filling; human brain; image slices; interpolation; iterative discrete cosine transform; nuclear medicine imaging; positron emission tomography; Detectors; Discrete cosine transforms; High-resolution imaging; Image resolution; Imaging phantoms; Interpolation; Iterative methods; Noise level; Nuclear medicine; Positron emission tomography; ROI; cosine domain data estimation; high resolution research tomograph (ECAT HRRT); interpolation; missing projection; positron emission tomography; quantitative evaluation; transradial bicubic interpolation;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record (NSS/MIC), 2009 IEEE
  • Conference_Location
    Orlando, FL
  • ISSN
    1095-7863
  • Print_ISBN
    978-1-4244-3961-4
  • Electronic_ISBN
    1095-7863
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2009.5401727
  • Filename
    5401727