DocumentCode :
3328084
Title :
Variations on the NEMA NU4-2008 testing procedures and effect on the performance measurement results
Author :
Elhami, Esmat ; Boulding, Josh ; Goertzen, Andrew L.
Author_Institution :
Dept. of Phys., Univ. of Winnipeg, Winnipeg, MB, Canada
fYear :
2011
fDate :
23-29 Oct. 2011
Firstpage :
3244
Lastpage :
3246
Abstract :
In this study we examine the effects of varying the testing procedures of the NEMA NU4-2008 standard for measuring sensitivity and image quality for a small animal PET scanner. In the current NEMA NU4-2008 standard, the sensitivity is measured by stepping a 22Na point source through the field of view of the scanner along the central Z axis. In some scanners it is not possible to automate the collection of this data, making it very tedious, if not impossible, to acquire the necessary data. As an alternative method, we explore using a long uniform line source extended beyond the field of view in the axial direction and validate this method by comparing our results with those obtained from the standard method. Two line sources were imaged, the first a 70-cm long plastic tube filled with 6 MBq of 18F (NEMA line source for clinical scanners) and the second a standard 20-cm long 68Ge sealed line source (0.90 MBq). Point source data were sorted and analyzed following the NEMA NU4- 2008 method to calculate sensitivity profiles to be plotted as a function of axial distance relative to the center of the field of view. Line source data were analyzed in a manner analogous to the NEMA NU2-2001 method for calculating sensitivity for clinical PET systems. The results from the 18F and 68Ge are in good agreement with those from a 22Na point source (0.93 MBq) using the NEMA standard methods. The difference in relative sensitivity between 22Na and the line sources are 0.90% for 18F and 1.7% for 68Ge line source. These results represent the equivalence of the sensitivity measurements using a line source or a point source.
Keywords :
fluorine; germanium; image scanners; phantoms; positron emission tomography; sensitivity; sodium; 18F line source; 22Na point source; 68Ge sealed line source; NEMA NU4-2008 testing procedures; axial direction; central Z axis; image quality; image sensitivity; performance measurement results; phantoms; plastic tube; point source data; radioactivity 0.90 MBq; radioactivity 0.93 MBq; radioactivity 6 MBq; size 20 cm; size 70 cm; small animal PET scanner; Materials; Positron emission tomography; Sensitivity;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2011 IEEE
Conference_Location :
Valencia
ISSN :
1082-3654
Print_ISBN :
978-1-4673-0118-3