DocumentCode
3328500
Title
Evaluation of a PET prototype using LYSO:Ce monolithic detector blocks
Author
Cuerdo, R. ; Sarasola, I. ; De Acilu, P. García ; Navarrete, J. ; Cañadas, M. ; Oller, I.C. ; Cela, J.M. ; Rato Mendes, Pedro ; Romero, L. ; Willmott, C.
Author_Institution
CIEMAT (Centro de Investig. Energeticas, Medioambientales y Tecnol.), Madrid, Spain
fYear
2011
fDate
23-29 Oct. 2011
Firstpage
3342
Lastpage
3346
Abstract
We have analyzed the performance of a PET demonstrator formed by two sectors of four monolithic detector blocks placed face-to-face. Both front-end and read-out electronics have been evaluated by means of coincidence measurements using a rotating 22Na source placed at the center of the sectors in order to emulate the behavior of a complete full ring. A continuous training method based on neural network (NN) algorithms has been carried out to determine the entrance points over the surface of the detectors. Reconstructed images from 1 MBq 22Na point source and 22Na Derenzo phantom have been obtained using both filtered back projection (FBP) analytic methods and the OSEM 3D iterative algorithm available in the STIR software package [1]. Preliminary data on image reconstruction from a 22Na point source with Ø = 0.25 mm show spatial resolutions from 1.7 to 2.1 mm FWHM in the transverse plane. The results confirm the viability of this design for the development of a full-ring brain PET scanner compatible with magnetic resonance imaging for human studies.
Keywords
brain; cerium; image reconstruction; lutetium compounds; medical image processing; neural nets; phantoms; positron emission tomography; solid scintillation detectors; yttrium compounds; Derenzo phantom; LYSO:Ce monolithic detector blocks; Lu1.8Y0.2SiO5:Ce; OSEM 3D iterative algorithm; PET prototype; STIR software package; filtered back projection analytic methods; front-end electronics; full-ring brain PET scanner; image reconstruction; magnetic resonance imaging; monolithic scintillator crystals; neural network algorithms; read-out electronics; sodium point source; Application specific integrated circuits; Continuous wavelet transforms; Crystals; Magnetic resonance imaging; Magnetosphere; Positron emission tomography; Three dimensional displays;
fLanguage
English
Publisher
ieee
Conference_Titel
Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2011 IEEE
Conference_Location
Valencia
ISSN
1082-3654
Print_ISBN
978-1-4673-0118-3
Type
conf
DOI
10.1109/NSSMIC.2011.6152605
Filename
6152605
Link To Document