Title :
Analysys and verification of calibration methods for fully polarimetric W-band radiometer
Author :
Kim, Sung-Hyun ; Moon, Nam-Won ; Kim, Yong-Hoon
Author_Institution :
Sch. of Inf. & Mechatron., Gwangju Inst. of Sci. & Technol., Gwangju, South Korea
Abstract :
The design method of calibration standard of fully polarimetric radiometer to measure the Stokes parameters at W-band is proposed. The information of 45° in a linear and a circular polarization are calibrated using the wire grid with thin Teflon substrate and the retardation plate which was implemented by dielectric plate with grove. The calibration standards show good performance on orthogonal channel polarization mixing (-17 to -25 dB), on mixing from the orthogonal channel into the polarimetric channels (-10.1 to -6.0 dB), and on mixing between polarization channels (-3.2 to -5.8 dB).
Keywords :
calibration; polarisation; radiometers; Stokes parameters; Teflon substrate; W-band; circular polarization; dielectric plate; linear polarization; orthogonal channel polarization mixing; plate grid; polarimetric channels; polarimetric radiometer; retardation plate; Calibration; Loss measurement; Microwave radiometry; Stokes parameters; Substrates; Temperature measurement; Wire; W-band; calibration; plate grid; polarization; radiometer; retardation plate;
Conference_Titel :
Geoscience and Remote Sensing Symposium (IGARSS), 2010 IEEE International
Conference_Location :
Honolulu, HI
Print_ISBN :
978-1-4244-9565-8
Electronic_ISBN :
2153-6996
DOI :
10.1109/IGARSS.2010.5651193