DocumentCode
3329826
Title
The Utah PET lesion detection database
Author
Kadrmas, Dan J.
Author_Institution
Dept. of Radiol., Univ. of Utah, Salt Lake City, UT, USA
fYear
2009
fDate
Oct. 24 2009-Nov. 1 2009
Firstpage
3693
Lastpage
3699
Abstract
Task-based assessment of image quality is a challenging but necessary step in evaluating advancements in PET instrumentation, algorithms, and processing. We have been developing methods of evaluating observer performance for detecting and localizing focal warm lesions using experimentally-acquired whole-body phantom data designed to mimic oncologic FDG PET imaging. This work describes a new resource of experimental phantom data that is being developed to facilitate lesion detection studies for the evaluation of PET reconstruction algorithms and related developments. A new large custom-designed thorax phantom has been constructed to complement our existing medium thorax phantom, providing two whole-body setups for lesion detection experiments. The new phantom is ~50% larger and has a removable spine/rib-cage attenuating structure that is held in place with low water resistance open cell foam. Several series of experiments have been acquired, with more ongoing, including both 2D and fully-3D acquisitions on tomographs from multiple vendors, various phantom configurations and lesion distributions. All raw data, normalizations, and calibrations are collected and offloaded to the database, enabling subsequent retrospective offline reconstruction with research software for various applications. The offloaded data are further processed to identify the true lesion locations in preparation for use with both human observers and numerical studies using the channelized non-prewhitened observer. These data have been used to study the impact of improved statistical algorithms, point spread function modeling, and time-of-flight measurements upon focal lesion detection performance, and studies on the effects of accelerated block-iterative algorithms and advanced regularization techniques are currently ongoing. Interested researchers are encouraged to contact the author regarding potential collaboration and application of database experiments to their projects.
Keywords
brain; data acquisition; image reconstruction; iterative methods; medical image processing; phantoms; positron emission tomography; statistical analysis; tumours; 2D acquisitions; 3D acquisitions; PET algorithms; PET instrumentation; PET processing; PET reconstruction algorithms; Utah PET lesion detection database; accelerated block-iterative algorithms; advanced regularization techniques; calibrations; custom-designed thorax phantom; experimentally-acquired whole-body phantom data; focal lesion detection performance; image quality; lesion distributions; normalizations; oncologic FDG PET imaging; point spread function modeling; retrospective offline reconstruction; spine-rib-cage attenuating structure; statistical algorithms; task-based assessment; time-of-flight measurements; water resistance open cell foam; Image databases; Image quality; Imaging phantoms; Immune system; Instruments; Lesions; Positron emission tomography; Reconstruction algorithms; Thorax; Whole-body PET;
fLanguage
English
Publisher
ieee
Conference_Titel
Nuclear Science Symposium Conference Record (NSS/MIC), 2009 IEEE
Conference_Location
Orlando, FL
ISSN
1095-7863
Print_ISBN
978-1-4244-3961-4
Electronic_ISBN
1095-7863
Type
conf
DOI
10.1109/NSSMIC.2009.5401862
Filename
5401862
Link To Document