Title :
Gas discharge switch evaluation for RHIC Beam Abort Kicker application
Author :
Zhang, Wensheng ; Sandberg, J.
Author_Institution :
Collider-Accelerator Dept., Brookhaven Nat. Lab., Upton, NY, USA
fDate :
30 June-3 July 2002
Abstract :
A gas discharge switch EEV HX3002 is being evaluated at Brookhaven National Laboratory as a possible candidate of RHIC Beam Abort Kicker modulator main switch. At higher beam energy and higher beam intensity, the switch stability becomes very crucial. The hollow anode thyratron used in the existing system is not rated for long reverse current conduction. The reverse voltage arcing caused thyratron hold-off voltage de-rating has been the main limitation of the system operation. To improve the system reliability, a new type of gas discharge switch has been suggested by Marconi Applied Technology for its reverse conducting capability.
Keywords :
beam handling equipment; discharges (electric); electron accelerators; pulsed power switches; Brookhaven National Laboratory; EEV HX3002; Marconi Applied Technology; RHIC Beam Abort Kicker; gas discharge switch; higher beam energy; higher beam intensity; hollow anode thyratron; long reverse current conduction; reverse conducting capability; reverse voltage arcing; switch stability; thyratron hold-off voltage de-rating; Anodes; Discharges; Laboratories; Magnetic modulators; Physics; Structural beams; Superconducting magnets; Switches; Thyratrons; Voltage;
Conference_Titel :
Power Modulator Symposium, 2002 and 2002 High-Voltage Workshop. Conference Record of the Twenty-Fifth International
Print_ISBN :
0-7803-7540-8
DOI :
10.1109/MODSYM.2002.1189520