DocumentCode
333026
Title
Dynamics of patellar tendon reflex in spastic multiple sclerosis patients
Author
Zhang, Li-Qun ; Wang, Guangzhi ; Sliwa, James ; Rymer, W. Zev
Author_Institution
Rehabilitation Inst. of Chicago, Northwestern Univ., Evanston, IL, USA
Volume
5
fYear
1998
fDate
28 Oct-1 Nov 1998
Firstpage
2313
Abstract
Patellar tendon reflexes were studied in fourteen normal subjects and ten multiple sclerosis (MS) patients. An instrumented hammer was used to tap the patellar tendon and record the tapping force, while the quadriceps EMG and knee extension torque were recorded isometrically as the reflex responses. The relationship between tapping force and reflex torque was characterized using several system measures: the tendon reflex gain (Gtr), contraction rate (Rc), half-relaxation rate (Rhr), contraction time (tc), half-relaxation time (thr), and reflex loop delay (td ). Gtr, Rc, and Rhr of the MS patients were significantly higher than their counterparts in normal controls (p<0.001 for all cases). td of the MS patients was significantly shorter than that of the normal group (p<0.005). G tr, Rc, and Rhr values correlated more closely with clinical measures of spasticity (Ashworth scale and tendon reflex scale) than did pure output measures (peak reflex torque and quadriceps EMG signals). Tendon reflexes were more repeatable in the MS population than in normal controls. The higher correlation to clinical measures and lower variation of Gtr, Rc, and Rhr indicate the potential values of these dynamic system measures in clinical practice as a more accurate and consistent approach towards quantification of the tendon jerk and spasticity
Keywords
biomechanics; biomedical measurement; diseases; electromyography; force measurement; torque measurement; Ashworth scale; clinical measures; contraction rate; contraction time; half-relaxation rate; half-relaxation time; instrumented hammer; isometric recording; knee extension torque; normal subjects; patellar tendon reflex dynamics; peak reflex torque; quadriceps EMG; reflex loop delay; spastic multiple sclerosis patients; spasticity; tapping force; tendon jerk; tendon reflex scale; Delay effects; Electromyography; Force measurement; Gain measurement; Instruments; Knee; Multiple sclerosis; Tendons; Time measurement; Torque measurement;
fLanguage
English
Publisher
ieee
Conference_Titel
Engineering in Medicine and Biology Society, 1998. Proceedings of the 20th Annual International Conference of the IEEE
Conference_Location
Hong Kong
ISSN
1094-687X
Print_ISBN
0-7803-5164-9
Type
conf
DOI
10.1109/IEMBS.1998.744751
Filename
744751
Link To Document