DocumentCode :
3330645
Title :
Effects of an axial target on the radiation of imploding wire arrays
Author :
Presura, R. ; Martinez, D. ; Stein, S. ; Plechaty, C. ; Neff, S.
Author_Institution :
Nevada Terawatt Facility, Univ. of Nevada, Reno, NV, USA
fYear :
2010
fDate :
20-24 June 2010
Firstpage :
1
Lastpage :
1
Abstract :
Thin wires have been added on the axis of cylindrical and conical wire arrays to investigate the effect of sheared plasma flows on the z-pinch stability. This addition significantly affected the x-ray emission of the conical wire arrays, while having little effect on that of the cylindrical ones. In addition, the material of the axial target had a strong influence on the radiation output. The experiments were performed on the 1 MA Zebra Z-pinch generator at the Nevada Terawatt Facility using conical and cylindrical wire arrays with and without a center wire. The arrays consisted of 8 aluminum wires 15 μm in diameter. Aluminum or copper wires of various thicknesses were used on axis.Broad spectral range radiation measured with bolometers indicated that the presence of an additional aluminum wire on the axis of the conical wire arrays causes an enhancement in the total energy emitted. No significant enhancement was observed in the case of adding aluminum wires on the axis of cylindrical arrays. The x-ray pinhole images of conical wire array pinches showed reduced emissivity of the plasma on axis with the presence of a center wire. One possible explanation is that the central wire remains cold throughout most of the pinch phase, preventing compression into a hot pinch. However, the hollow emissivity profile was not noticeable for the case of cylindrical wire arrays, even for the case of a 50 μm aluminum axial wire. To clarify this issue, the emission of conical wire arrays with 50 μm copper central wire was compared with that of identical arrays with 50 μm aluminum central wire. The x-ray energy yield was significantly higher when using a copper wire. The emissivity of the axial plasma region was higher as well. Moreover, the energy of the photons emitted from the axial region surpassed 3 keV, indicating a high temperature source. At the plasma temperature required for the observed photon energies, aluminum would be fully ionized, so it- emissivity would be reduced. In addition, the pinch diameter measured from x-ray pinhole images, was much smaller when using a copper center wire than in the case of an aluminum center wire. The reduced diameter of the copper pinch compared to that of the aluminum pinch and the dependence on the atomic number of the central wire material indicate that radiative cooling plays a significant role in the conical wire array pinch dynamics.
Keywords :
Z pinch; aluminium; copper; exploding wires; explosions; plasma X-ray sources; plasma diagnostics; plasma flow; plasma instability; plasma temperature; plasma transport processes; Al; Cu; Nevada terawatt facility; X-ray emission; X-ray energy yield; X-ray pinhole images; Z-pinch stability; Zebra Z-pinch generator; aluminum center wire; axial plasma region; axial target effects; bolometer; broad spectral range radiation; central wire material; conical wire array emission; conical wire array pinch dynamics; copper center wire; current 1 MA; cylindrical wire array; hollow emissivity profile; imploding wire array radiation; photon energy emission; pinch diameter measurement; plasma temperature; radiative cooling; sheared plasma flow; size 15 mum; total energy emission; Aluminum; Copper; Energy measurement; Plasma materials processing; Plasma stability; Plasma temperature; Plasma x-ray sources; Thickness measurement; Wire; X-ray imaging;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Plasma Science, 2010 Abstracts IEEE International Conference on
Conference_Location :
Norfolk, VA
ISSN :
0730-9244
Print_ISBN :
978-1-4244-5474-7
Electronic_ISBN :
0730-9244
Type :
conf
DOI :
10.1109/PLASMA.2010.5534088
Filename :
5534088
Link To Document :
بازگشت