High-low impedance transformer using transmission line method
Author
Ruei-Ying Fang ; Chia-Fen Liu ; Chieh-Yu Liao ; Chun-Long Wang
Author_Institution
Dept. of Electron. Eng., Nat. Taiwan Univ. of Sci. & Technol., Taipei, Taiwan
fYear
2013
fDate
24-27 Oct. 2013
Firstpage
185
Lastpage
189
Abstract
In this paper, a simple transmission line method is proposed to precisely predict the center frequency of the compact high-low impedance transformer. It has been shown that the center frequency of the return loss stays at 3 GHz even though the electrical length θT reduces greatly. Besides, the compact high-low impedance transformer with θT = 60° yields 35.89% area-saving and maintains the same 15-dB bandwidth as compared with the conventional quarter-wavelength transformer. In order to verify the simulation results, back-to-back transformers are fabricated and measured where the measurement results are in good agreement with the simulation results.
Keywords
impedance convertors; transmission line theory; back-to-back transformers; bandwidth 3 GHz; center frequency; high-low impedance transformer; quarter-wavelength transformer; return loss; transmission line method; Frequency measurement; Impedance; Insertion loss; Loss measurement; Microstrip; Power transmission lines; Transmission line measurements; Compact; high-low impedance; quarter-wavelength; transformer;