Title :
Advanced cathode and anode research at the Air Force Research Laboratory
Author :
Shiffler, Donald ; Ruebush, M. ; LaCour, M. ; Golby, K. ; Cartwright, K. ; Haworth, M.
Author_Institution :
Air Force Res. Lab., Kirtland AFB, NM, USA
fDate :
30 June-3 July 2002
Abstract :
High power microwave (HPM) tubes require currents and voltages generally in excess of 1 kA and 100 kV. Traditionally such systems have operated in poor vacuum (>10-6 torr) and on a single shot basis. Current work at the Air Force Research Laboratory (AFRL) has been directed toward high vacuum and high repetition rate systems, necessitating a complete revision of standard HPM "techniques". In this paper we discuss cathode and anode research in the HPM area, defining the figures of merit for AFRL cathodes and anodes. Several novel cathode and anode designs are discussed, with accompanying experimental results. Indeed, results have been so encouraging that we believe these classes of novel cathodes and anodes have application beyond HPM as replacements for thermionic cathodes.
Keywords :
anodes; cathodes; microwave tubes; pulsed power supplies; Air Force Research Laboratory; General Rep-rate Universal Multi-purpose Pulser; Rep-rate Test Pulser; anode; cathode; figures of merit; high power microwave tubes; high repetition rate system; high vacuum system; poor vacuum; Anodes; Cathodes; Diodes; Geometry; Laboratories; Microwave devices; Polymers; Pulse measurements; Testing; Vacuum systems;
Conference_Titel :
Power Modulator Symposium, 2002 and 2002 High-Voltage Workshop. Conference Record of the Twenty-Fifth International
Print_ISBN :
0-7803-7540-8
DOI :
10.1109/MODSYM.2002.1189575