• DocumentCode
    3332347
  • Title

    Electromagnetic coupling into rectangular rack-and-panel connectors

  • Author

    Hoeft, Lothar O. ; Montoya, Mauricio T. ; Hofstra, Joseph S.

  • Author_Institution
    BDM Federal Inc., Albuquerque, NM, USA
  • fYear
    195
  • fDate
    14-18 Aug 195
  • Firstpage
    475
  • Lastpage
    479
  • Abstract
    Measurement of the surface transfer impedance of both standard and EMI rack-and-panel connectors from 1 kHz to 100 MHz showed that the standard rack-and-panel connector provides essentially no electromagnetic shielding because it contains no positive mechanism for maintaining electrical contact between the plug and receptacle. Supplementary grounding devices reduce the transfer impedance to desirable levels for frequencies below a few tens of kHz. Electromagnetic shielding at high frequencies is minimal. Spring fingers around the periphery of the plugs were very effective for maintaining electrical contact between the plug and receptacle and preventing electromagnetic coupling through the plug/receptacle interface. Control of the electromagnetic coupling through the plug/backshell interface was essential for good high frequency shielding performance. Gaskets installed in the plug/backshell interface were electromagnetically effective but cumbersome to install. At 100 MHz, the surface transfer impedance was dominated by the bonding impedance between the receptacle and the chassis. When spring fingers and a gasketted backshell were used, the transfer impedance of the rack-and-panel connector slowly increased from a fraction of a milliohm at low frequencies to several milliohms at high frequencies. This is about equivalent to the electromagnetic shielding expected of a quality circular connector and a good backshell
  • Keywords
    electric connectors; electric impedance measurement; electromagnetic interference; electromagnetic shielding; 1 kHz to 100 MHz; EMI; bonding impedance; chassis; circular connector; electrical contact; electromagnetic coupling; electromagnetic shielding; gaskets; grounding devices; high frequencies; high frequency shielding performance; low frequencies; plug; plug/backshell interface; plug/receptacle interface; receptacle; rectangular rack and panel connectors; spring fingers; surface transfer impedance; Connectors; Contacts; Electromagnetic coupling; Electromagnetic shielding; Fingers; Frequency; Measurement standards; Plugs; Springs; Surface impedance;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electromagnetic Compatibility, 1995. Symposium Record., 1995 IEEE International Symposium on
  • Conference_Location
    Atlanta, GA
  • Print_ISBN
    0-7803-3608-9
  • Type

    conf

  • DOI
    10.1109/ISEMC.1995.523604
  • Filename
    523604