DocumentCode :
3332491
Title :
Measured temperature dependence of scintillation camera signals read out by geiger-Müller mode avalanche photodiodes
Author :
Hunter, William C J ; Miyaoka, Robert S. ; MacDonald, L.R. ; Lewellen, Thomas K.
fYear :
2009
fDate :
Oct. 24 2009-Nov. 1 2009
Firstpage :
2662
Lastpage :
2665
Abstract :
We are developing a prototype monolithic scintillation camera with optical sensors on the entrance surface (SES) for use with statistically-estimated depth-of-interaction in a continuous scintillator. We opt to use Geiger-Muller mode avalanche photodiodes (GM-APDs) for the SES camera since they possess many desirable properties; for the intended application (SES and PET/MR imaging), they offer a thin attenuation profile and an operational insensitivity to large magnetic fields. However, one issue that must be addressed in using GM-APDs in an RF environment (as in MR scanners) is the thermal dissipation that can occur in this semiconductor material. Signals of GM-APDs are strongly dependent on junction temperature. Consequently, we are developing a temperature-controlled GM-APD-based PET camera whose monitored temperature can be used to dynamically account for the temperature dependence of the output signals. Presently, we aim to characterize the output-signal dependence on temperature and bias for a GM-APD-based scintillation camera. We´ve examined two GM-APDs, a Zecotek prototype MAPD-3N, and a SensL commercial SPMArray2. The dominant effect of temperature on gain that we observe results from a linear dependence of breakdown voltage on temperature (0.071 V/°C and 0.024 V/°C, respectively); at 2.3 V excess bias (voltage above breakdown) the resulting change in gain with temperature (without adjusting bias voltage) is -8.5% per°C for the MAPD-3N and -1.5 % per °C for the SPMArray2. For fixed excess bias, change in dark current with temperature varied widely, decreasing by 25% to 40% as temperature was changed from 20°C to 10°C and again by 20% to 35% going from 10°C to 0°C. Finally, using two MAPD-3N to read out a pair of 3.5-by-3.5-by-20 mm3 Zecotek LFS-3 scintillators in coincidence, we observe a decrease from 1.7 nsec to 1.5 nsec in coincidence-time resolution as we lowered tempera- - ture from 23°C to 10°C.
Keywords :
avalanche photodiodes; nuclear electronics; optical sensors; prototypes; readout electronics; scintillation counters; Geiger-Muller mode avalanche photodiodes; an thermal dissipation; coincidence-time resolution; continuous scintillator; dark current; junction temperature; measured temperature dependence; operational insensitivity; optical sensors; prototype monolithic scintillation camera; scintillation camera signals read out; statistically-estimated interaction depth; temperature-controlled; thin attenuation profile;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium Conference Record (NSS/MIC), 2009 IEEE
Conference_Location :
Orlando, FL
ISSN :
1095-7863
Print_ISBN :
978-1-4244-3961-4
Electronic_ISBN :
1095-7863
Type :
conf
DOI :
10.1109/NSSMIC.2009.5401995
Filename :
5401995
Link To Document :
بازگشت